Description
The ideal solution for low power frost protection or temperature maintenance on metallic and non-metallic types, valves, roof gutters, drain pipes, pumps, water taps, small water tanks, and boiler condensate pipes etc.
- Supplied in 20m drums (can be cut to any length)
- NOTE: A termination kit is required for each run of trace heating cable
- Self-regulating - output automatically adjusts to suit the prevailing conditions, for the lower the ambient temperature the higher the output
- Tough cable protection with tin-plated, copper braiding and a thermoplastic and outer sleeve
- Moisture proof and UV resistant
- Will not overheat or burn out even when overlapped
Each Kit contains
- 20m length trace heating cable
- 1 termination kit
- 6 x heat shrink sleeves (various)
- 2 x wire pins (ferrules)
- connection insulator
- pin type cable socket
- M25 cable gland
Technical Specification
- Dimensions: 13.6 x 5.5mm
- 230V, nominal output 10W/m @ 10°C ambient temperature
- Max exposure temperate: 80°C (De-energise), 65°C (energised)
- Min installation temperature: -45°C
- Min bending radius: 25m
- Max cable run: 144m @ 10°C (16A) power